2
Assembly and Installation
1. Attach the mounting screws provided (14) to the mounting plate (13) and the secure it with hexagonal nut (12).
2. Secure the mounting plate (13) to the outlet box (15) using the screws (11) provided.
3. Wiring Connections: Connect the white wire(s) from the fixture to the white wire of the supply circuit. Connect the black wire(s)
from the fixture to the black wire of the supply circuit. Connect the green or bare copper wire to the ground wire of the supply
circuit. Use UL/CSA listed wire connectors suitable for the size type, and number of conductors. No loose strands or loose wires
should be present. Secure wire connectors with UL/CSA listed electrical tape.
4. Attach the base of the fixture onto the mounting plate (13) and tighten the finial (6) onto the mounting plate screws (14)
to secure the fixture.
5. Place the glass shade (4) on the socket (5), and then put the fixing ring (3) onto the socket. Tighten the socket ring (2)
to secure the glass shade (4).
6. Screw the bulb (1) into the socket (5).
Relamping
1. Turn off the lamp at the switch and the main power supply.
2. Make sure the bulb is cool enough before touching.
3. Remove the old bulb and insert a new type A Medium base 60W Max. bulb into the socket.
4. Restore the main power and turn on at the switch.
CAUTION: Refer to the relamping label near the lampholder for recommended bulb type and maximum wattage allowed
(bulb sold separately).
1. Bulb
2. Socket Ring
3. Fixing Ring
4. Glass Shade
5. Socket
6. Finial
7. Fixture black wire
8. Wire Connector
9. Fixture Neutral (white) wire
10. Ground wire
11. Screw
12. Hexagonal Nut
13. Mounting Plate
14. Screw
15. Outlet Box
16. Ground Screw